FRONT MOUNTINGS
Features
1)Standard 4 hole front panel mounting.
2)Knob/Handle operatable.
3)Suitable for all switching angle and spring return switches.
4)Front assembly in four different colours, Yellow/Red, Grey/Black Black/Black, Aluminium Finish.
FRONT MOUNTINGS
Features
1)Standard 4 hole front panel mounting.
2)Knob/Handle operatable.
3)Suitable for all switching angle and spring return switches.
4)Front assembly in four different colours, Yellow/Red, Grey/Black Black/Black, Aluminium Finish.
Changeover Switches, also called Double Throw Switches, are available with OFF and without OFF. These are used to operate two different circuits, with different number of inputs and outputs. Changeover Switches without jumpers (potential free contacts) are used to connect two different circuits from two different sources, with two different operating voltages or any other incompatible lines. All contacts by default are “Break Before Make” (BBM) type to avoid overlapping of different circuits while overlapping changeover contacts. “Make Before Break” (MBB) type are offered against specific requirements.
Applications: Power Supply to Generator Changeover, Auto/Manual changeover, Standby/Remote Changeover and other special application circuits. Mainly used in Distribution Panels, UPS etc.
Changeover with Off
Stayput
Description | 60 Degree | No of stages | Description | 90 Degree |
Programme Code | Programme Code | |||
1 Pole | SP 61025 | 1 | 1 Pole | 61151 |
2 Pole | SP 61026 | 2 | 2 Pole | 61152 |
3 Pole | SP 61027 | 3 | 3 Pole | 61153 |
4 Pole | SP 61028 | 4 | 4 Pole | 61154 |
5 Pole | SP 61029 | 5 | – | – |
6 Pole | SP 61030 | 6 | – | – |
7 Pole | SP 61031 | 7 | – | – |
8 Pole | SP 61032 | 8 | – | – |
Spring return
45 Degree Spring Return to “0” | No of stages | Spring Return from 1 to “0” | ||
Description | Programme code | Description | Programme code | |
1 Pole | SP 61361 | 1 | 1 Pole | 61364 |
2 Pole | SP 61362 | 2 | 2 Pole | 61365 |
3 Pole | SP 61363 | 3 | 3 Pole | 61369 |
Without Jumper
60 Degree Stayput without Jumper | No of stages | 45 Degree Spring Return without Jumper | ||
Description | Programme code | Description | Programme code | |
1 Pole without jumper | SP 61625 | 1 | 1 Pole without jumper | 61761 |
2 Pole without jumper | SP 61626 | 2 | 2 Pole without jumper | 61762 |
3 Pole without jumper | SP 61627 | 3 | – | – |